HIGH 7.0 NVD

CVE-2026-87662

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processin

Brocade Fabric versions before 9.2.2d and 10.0.0 through 10.0.0a1 handling of specific download protocols utilizes unsanitized parameter strings. When processing upgrade requests, parameters are converted into system command strings and executed through a system shell interface. Because control characters and shell metacharacters in fields like the host or file path are not stripped or sanitized, an attacker can execute arbitrary shell commands with the firmware management daemon's elevated privileges.

References

Published: 2026-10-08 · Source: NVD · Feed updated: 2026-10-12
This high severity vulnerability with a CVSS score of 7.0 was published on 2026-10-08 via NVD.
vulnfeed aggregates 13827 vulnerabilities from NVD, CISA KEV, Ubuntu, Debian, Red Hat, Kubernetes, Exploit-DB, OSS-Security, GitHub and OpenStack — updated every 4 hours.