LOW 2.4 NVD
CVE-2026-85068
Network UPS Tools is a collection of programs which provide a common interface for monitoring and administering UPS, PDU and SCD hardware. From 2.4.2 through 2.
Network UPS Tools is a collection of programs which provide a common interface for monitoring and administering UPS, PDU and SCD hardware. From 2.4.2 through 2.8.5, ippon_command in drivers/blazer_usb.c partially initializes char tmp[64] with a short Megatec status query and then passes a fixed eight-byte chunk to usb_control_msg. A malicious firmware-controlled USB device presenting the Mustek Powermust VID 0x06da and Mustek Powermust PID 0x0003 matches blazer_usb_id, selects ippon_subdriver, and can receive the uninitialized trailing stack bytes during normal polling. The disclosure is bounded and read-only, requires physical or supply-chain access to the USB bus, and has no established integrity or availability impact. This issue is scheduled to be fixed in version 2.8.6.
References
- https://github.com/networkupstools/nut/commit/30d56d4282f823949b40763d5c76461c7dd107b3
- https://github.com/networkupstools/nut/pull/3529
- https://github.com/networkupstools/nut/security/advisories/GHSA-fjxc-2vpv-mqc8
This low severity vulnerability with a CVSS score of 2.4 was published on 2026-11-05 via NVD.
vulnfeed aggregates 16809 vulnerabilities from NVD, CISA KEV,
Ubuntu, Debian, Red Hat, Kubernetes, Exploit-DB, OSS-Security, GitHub and OpenStack — updated every 4 hours.